This article describes how to deploy an App Connector for a data center or universal CPE (uCPE) running VMware ESXi.
Preparing to Provision the ESXi App Connector
These are the prerequisites to prepare to create the VMware ESXi App Connector and connect it to the Cato Cloud:
Download the OVA image for the ESXi vSocket and App Connector from the Cato Networks repository, see Socket and vSocket Image Files
Internet connectivity for the WAN1 interface on the App Connector VM
Public DNS service must be available for the LAN interfaces on the App Connector VM
Only attach 3 network interfaces (NICs) to the VM. Attaching more than 3 NICs may result in issues for the App Connector
Create an App Connector
When you create an App Connector, you can choose the behavior for connecting to a preferred PoP in the Cato Cloud:
Disabled - the App Connector automatically connects to the best available PoP (default)
Enabled - Select the PoPs to which the connector attempts to connect to
When Preferred PoP is enabled, you can restrict an App Connector to only connect to the Preferred PoP Locations that you configure. In this case, the connector doesn't connect to a non-preferred PoP location despite any connectivity or performance issues that it is experiencing. When you use this option, you must define a primary and secondary PoP location for the App Connector.
Once the App Connector is created in the CMA, copy the serial number, as you will need to provide it when deploying the App Connector in your cloud environment.

To create an App Connector in the CMA:
From the navigation menu, click Access > App Connector, and then click New.
Enter the information in the General section, such as Connector Name and Country.
Under Type, click Virtual.
In the Connector Group section, select an existing App Connector group from the list or enter a name to create a new group.
Under Preferred PoPs, select the behavior
Disabled - the App Connector tries to connect to the best available PoP
Enabled - Select the Primary and Secondary PoP locations that the connector tries to connect to
Enabled and Only connect to the preferred PoPs - Only connect to the Primary or Secondary PoP location
Click Apply.
Best Practices for Deploying an ESXi App Connector
When you deploy an ESXi App Connector, we recommend creating the VM directly from the OVA file in vSphere, instead of creating a VM first and then attaching the OVA file to it. Deploying directly from the OVA file ensures that all necessary hardware settings are correctly applied and helps avoid potential hardware compatibility issues.
If you have already deployed and need to add memory, you can do so without having to redeploy your App Connector.
Make sure to meet the VM App Connector minimum requirements for both vSphere and VM resources, as documented below.
Deploying the VM in ESXi
In vSphere, deploy a new VM for the App Connector based on the Cato OVA template. The performance of the ESXi App Connector depends on the hardware configuration of the ESXi host.
Minimum Requirements for the App Connector
These are the minimum requirements for the VM App Connector:
vSphere requirements:
Minimum ESXi version - ESXi 8.0
Image format - OVA
Required VM resources:
2 vCPUs
4 GB RAM
At least 7 GB HDD
Deploying the VM
Deploy the ESXi template to a VM in vSphere and configure the settings for the App Connector interfaces.
To deploy the App Connector to a VM:
Right-click the ESXi host or folder and select Deploy OVF Template.
In the Select an OVF template window, select Local file and click Choose Files.
Select the OVA file with the App Connector image. Click Next.
In the Select a name and folder window, enter a VM name and select the location. Click Next.
In Select a compute resource, select the host for the VM. Click Next.
vSphere validates the settings for the OVF template.
In the Review details window, click Next.
In the Select storage window, select the virtual disk. Click Next.
In the Select networks window, configure each Destination Network according to the following Socket Source Networks:
LAN interface
Management interface
WAN interface
Click Next.
In the Customize template window, enter the serial number for the App Connector in the Cato Management Application.
You need to enter the exact serial number (including dashes).
Click Next.
In the Ready to complete window, click Finish. vSphere deploys the App Connector VM.
If necessary, click Edit Settings and change the resources and networks for the VM.