--- title: "How to Change the Socket Model for a Site" slug: "how-to-change-the-socket-model-for-a-site" tags: ["Sockets", "Sites"] updated: 2026-11-09T08:53:24Z published: 2026-11-09T08:53:24Z canonical: "knowledge.catonetworks.com/how-to-change-the-socket-model-for-a-site" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.catonetworks.com/llms.txt > Use this file to discover all available pages before exploring further. # How to Change the Socket Model for a Site This article describes how to replace an existing physical Socket model with a different physical Socket model. ## Overview You can change the Socket model for a site, for example, upgrade a site from X1500 to X1700 Socket. When you unassign and disconnect the Socket, the site gets disconnected from the Cato Cloud. All connectivity is restored once the new Socket is assigned to the site. To change the Socket model for a site with Socket High Availability (HA), you need to unassign both Sockets and replace them with the new Sockets. ## Preparing to Replace a Socket Before the Socket model is replaced, you are advised to consider the following preparatory steps: - Before you change the Socket site type, make sure that the S/N (and the MAC address for the X1500 Socket model) of the new Socket is available in the **Socket Inventory** screen (Administration > Socket Inventory). The Socket must be available in the Socket Inventory to connect successfully. - If there are static IP addresses configured for the existing Socket’s WAN interfaces, we recommend that you log in to the Socket WebUI and copy the static IP configuration. These static IP addresses are not migrated to the new Socket model, and you need to configure them again. - For X1700 Sockets that use an add-on card, you must remove the card and re-assign the ports before you change to a different Socket. - When moving a LAN configuration to a different Socket port, use the **Exchange Ports** option to preserve the defined networks. Disabling the original port and enabling another port instead causes the loss of the defined networks. For instructions, see [Exchanging Socket Ports](https://knowledge.catonetworks.com/docs/exchanging-socket-ports). > [!TIP] > IMPORTANT! > > Replacing a Socket causes downtime, we recommend scheduling the replacement during a maintenance window. ## Mapping the Socket Ports When you migrate from one Socket to another, the ports are mapped differently for each Socket model. The Socket ports are based on the IDs in the Socket screen (Network > Site Configuration > Socket), not the names that you configure for the ports. **Note:** You can migrate interchangeably between all Socket models as demonstrated below. ### Changing X1500 and X1600 Sockets The X1500 Socket ports map to the following ports on the X1600 Socket: | X1500 Socket | X1600 Socket | | --- | --- | | WAN1 | Port 1 | | WAN2 | Port 2 | | LAN1 | Port 5 | | LAN2 | Port 6 | | USB1 | USB1 | | USB2 | USB2 | ### Changing X1500 and X1700 Sockets The X1500 Socket ports map to the following ports on the X1700 Socket: | X1500 Socket | X1700 Socket | | --- | --- | | WAN1 | Port 1 | | WAN2* | Port 2 or port 3 | | LAN1* | Port 2 or port 3 | | LAN2 | Port 4 | | USB1 | Not migrated | | USB2 | Not migrated | * This mapping depends if the X1500 Socket has one or two active ports for WAN traffic: - If WAN2 is **used as a secondary WAN link**, it maps to port 2 and LAN1 maps to port 3 - If WAN2 is **not used for WAN traffic**, it maps to port 3 and LAN1 maps to port 2 ### Changing X1600 and X1700 Sockets The X1600 Socket ports map to the following ports on the X1700 Socket: **Port Types:** X1700 Ports 3 and 4 are copper Ethernet ports. X1600 Ports 3 and 4 are SFP fiber ports, while Ports 5–8 are copper Ethernet ports. Do not move cables based only on matching port numbers. **Migrating from X1700 to X1600 Socket** During migration, the X1700 port configurations move to the following physical ports on the X1600: - X1700 port 3 to X1600 port 5 - X1700 port 4 to X1600 port 6 Connect the copper cables to these physical X1600 ports. **Migrating from X1600 to X1700** During migration, the X1600 port configurations move to the following physical ports on the X1700: - X1600 port 5 to X1700 port 3 - X1600 port 6 to X1700 port 4 Connect the copper cables to these physical X1700 ports. This table shows the full mapping of the Socket ports: | X1600 Socket | X1700 Socket | | --- | --- | | Port 1 | Port 1 | | Port 2 | Port 2 | | Port 5 | Port 3 | | Port 6 | Port 4 | | N/A | Port 5 | | N/A | Port 6 | | Port | Port 7 | | Port | Port 8 | | USB1 | Not migrated | | USB2 | Not migrated | X1700 ports 5 and 6 are not mapped to X1600 ports. ### Migrating Ports for X1700 and X1600 Sockets **Before Migration: Move Connections from Add-On Ports** If the existing X1700 Socket uses add-on ports, move each connection to one of the eight built-in ports before migrating, as follows: 1. In the CMA, use the [Exchanging Socket Ports](https://knowledge.catonetworks.com/docs/en/exchanging-socket-ports) feature to move the port configuration to a built-in port. 2. Move the cable to the corresponding physical port on the X1700 Socket. 3. After moving all add-on connections, remove the add-on card from the CMA. 4. Power off the Socket, [remove the add-on card](/v1/docs/socket-x1700-deployment-guide#x1700-socket-network-card-addon) from the Socket. 5. Power on the Socket. 6. Change the site to X1600 Socket (see below, [Changing the Socket Model for a Site](/v1/docs/how-to-change-the-socket-model-for-a-site#changing-the-socket-model-for-a-site)) **After Migration: Check the Port Assignments** Wait five minutes after assigning the replacement Socket for its configuration to download. From **Network > Sites**, select the site and open **Site Configuration > Socket**. Confirm that each LAN configuration matches the physical port where you connected its cable. The **Port Name** column does not indicate the physical port number. After an X1700-to-X1600 migration, the physical X1600 port 3 is named **5**, and the physical port 4 is named **6**. Check the physical port and its configuration before selecting ports to exchange. Exchange ports only if you need to move a configuration. > [!TIP] > Important: > > When moving a connection to a different port, use the **Exchange Socket Ports** feature in the CMA to move its configuration, then move the cable. Do not disable the original port and enable another port instead. Disabling a port deletes all network settings associated with it. ## Changing the Socket Model for a Site Use the Cato Management Application to change the site type to the new Socket model. Then disconnect the existing Socket, and connect the network cables to the new Socket. When the new Socket is ready, assign it to the new site. **Important:** When moving a LAN configuration to a different Socket port, use the **Exchange Ports** option to preserve the defined networks. Disabling the original port and enabling another port instead can cause the loss of the defined networks. For instructions, see [Exchanging Socket Ports](https://knowledge.catonetworks.com/docs/exchanging-socket-ports). **To change the Socket model for a site:** 1. In the Cato Management Application, unassign the existing Socket from the site. For more about unassigning a Socket, see [Managing Sockets](/v1/docs/managing-sockets). 1. From the navigation menu, click **Network > Sites**, and select the site with the Socket you are unassigning. 2. From the navigation menu, click **Site Configuration > Socket**. ![unassign.png](https://cdn.document360.io/81d0367c-2b69-4ba8-b412-1c8f46ce677e/Images/Documentation/24247834902813.png?sv=2026-02-06&spr=https&st=2026-11-14T15%3A39%3A11Z&se=2026-11-14T16%3A39%3A11Z&sr=c&sp=r&sig=K00ZPN8C49KaP87%2BmVCyF0SkjPaG7WC0OLUK69XL%2BOo%3D) 3. From the **Actions** menu of the site you are unassigning, select **Unassign**. A warning window opens. 4. Click **OK**. The Socket is unassigned from the site. The account receives a new **Notification** to activate a new Socket. 2. From the navigation menu, click **Network > Sites**, and confirm that the **Connectivity Status** for the site is **Disconnected**. 3. Change the site's **Connection Type**. 1. From the navigation menu, click **Network > Sites** and select the site. 2. Expand the **General** section. 3. From the **Connection Type** drop-down menu, select the new Socket model site type (for example, Socket X1700). ![Change_Connection_Type.png](https://cdn.document360.io/81d0367c-2b69-4ba8-b412-1c8f46ce677e/Images/Documentation/24247790281373.png?sv=2026-02-06&spr=https&st=2026-11-14T15%3A39%3A11Z&se=2026-11-14T16%3A39%3A11Z&sr=c&sp=r&sig=K00ZPN8C49KaP87%2BmVCyF0SkjPaG7WC0OLUK69XL%2BOo%3D) 4. Click **Save**. 4. Connect the WAN port of the new Socket (WAN1 for the X1500 or port **1** for the X1600 and X1700 Sockets) to the Internet. The Socket automatically upgrades to the newest Socket OS version. 5. Open the notification area ![notification.png](https://cdn.document360.io/81d0367c-2b69-4ba8-b412-1c8f46ce677e/Images/Documentation/24247790354077.png?sv=2026-02-06&spr=https&st=2026-11-14T15%3A39%3A11Z&se=2026-11-14T16%3A39%3A11Z&sr=c&sp=r&sig=K00ZPN8C49KaP87%2BmVCyF0SkjPaG7WC0OLUK69XL%2BOo%3D) (in the upper-right menu bar), and expand the **Activate New Socket** message. ![Activate_Socket.png](https://cdn.document360.io/81d0367c-2b69-4ba8-b412-1c8f46ce677e/Images/Documentation/24247774101405.png?sv=2026-02-06&spr=https&st=2026-11-14T15%3A39%3A11Z&se=2026-11-14T16%3A39%3A11Z&sr=c&sp=r&sig=K00ZPN8C49KaP87%2BmVCyF0SkjPaG7WC0OLUK69XL%2BOo%3D) 6. Click **Accept**. Select the site that the Socket is assigned to. 7. For sites using a Socket High Availability (HA) configuration: If necessary, change the Socket MGMT interface IP address to meet your requirements. ## Replacing Sockets for an HA Site Use this procedure to replace both physical Sockets at an HA site. Schedule a maintenance window because unassigning both Sockets disconnects the site from the Cato Cloud. Before the maintenance window, confirm that both replacement Sockets are available in **Administration > Socket Inventory**. If required, configure the static WAN settings on each replacement Socket. See [Assigning a Static IP to a Socket](https://knowledge.catonetworks.com/docs/en/assigning-a-static-ip-to-a-socket). If you are changing Socket models, review the applicable port mapping in [Mapping the Socket Ports](/docs/how-to-change-the-socket-model-for-a-site#mapping-the-socket-ports) before moving cables. **To replace the HA pair:** 1. Unassign both existing Sockets from the site. 2. If you are changing Socket models, open the site’s **General** settings, select the replacement model as the **Connection Type**, and click **Save**. 3. Move the WAN and LAN cables to the appropriate ports on both replacement Sockets, using the applicable port mapping. 4. Let both replacement Sockets connect to the Cato Cloud and complete any required upgrade. 5. Accept each **Activate New Socket** notification and assign both replacement Sockets to the existing site. 6. Wait for both Sockets to download their configuration. 7. If a LAN configuration needs to move to a different port, use the **Exchange Ports** option. See [Exchanging Socket Ports](https://knowledge.catonetworks.com/docs/en/exchanging-socket-ports). Disabling the original port and enabling another port instead can cause the loss of the defined networks. 8. If necessary, update the Socket MGMT interface IP addresses to meet your requirements. 9. Confirm that both Sockets are connected, HA status is ready, the LAN and VRRP port destinations match the intended configuration, and all LAN segments are reachable.