--- title: "X1500 Socket Electrical Specifications" slug: "x1500-socket-electrical-specifications" tags: ["Networking", "Sockets"] updated: 2026-06-22T09:21:20Z published: 2026-06-22T09:21:20Z canonical: "knowledge.catonetworks.com/x1500-socket-electrical-specifications" --- > ## Documentation Index > Fetch the complete documentation index at: https://knowledge.catonetworks.com/llms.txt > Use this file to discover all available pages before exploring further. # X1500 Socket Electrical Specifications This article shows the details for the power consumption details and specifications for Cato X1500 and X1500B Socket models. ## X1500 BTU/HR Details | Socket Model | Idle | Full Loading | | --- | --- | --- | | X1500 | 16 | 41 | | X1500B | 12.3 | 14.5 | ## General Description This specification defines the input, output characteristics and performance requirements for 24 watts switching mode AC to DC adapter. ## Electrical Specifications for X1500 and X1500B Socket Models - Input Requirement - Input Voltages And Frequency Normal Voltages - Normal Voltages 100-240VAC Voltage Variation Range 90-264 VAC - Normal Frequency 50-60Hz - Frequency Variation Range 47Hz to 63 Hz - Input Current AC input current shall not exceed 0.6A MAX, when operated at100-240VAC with no load to full load. - Inrush Current The inrush current must be limited to 50A when operated at 240VAC. Inrush current is measured at an ambient temperature of 25 °C with the test temperature stabilized in the power off condition until at ambient temperature - Power Consumption The power consumption shall not exceed 0.075W when operated at normal voltage 100-240VAC with no load - Input Protection - Input Current Protection A fuse with a rating of 2.0A shall be installed on the input line side near the input connector to provided protection to the power supply - Output Requirement - Output Voltage - Current And Ripple Under any combinations of line and load variation and environmental conditions, output shall remain with in the tolerance defined below: > [!NOTE] > - Output voltages shall be measured at output connector. > - Ripple measurements shall be made with an oscilloscope of at least 20 MHz bandwidth. Output shall be bypassed at the connector with a 0.1uF ceramic disk capacitor and a 10uF electrolytic capacitor to simulate system loading at temperature 25°C. - Input normal voltage: 100 - 240VAC - Output Nominal Voltage - 12VDC - Output Regulation +/- 5% - Minimum Load (A) 0 - Maximum Load(A) 0 - Ripple (m Vp-p) 200 - Output power (w) 24 - Short Circuit Protection and Over Current Protection - The power supply shall be protected from damage of accidentally shorting Output for a long time period or over current Protection (2.2-3.0)A and auto-recovery when the fault is removed.